Home > Archive > Home Repair forum > June 2005 > furnace leaking









You are viewing an archived Text-only version of the thread. To view this thread in it's original format and/or if you want to reply to this thread please [click here]

 

Author furnace leaking
Mike Cummins

2005-06-30, 4:25 am

I have an older model Sears furnace. Furnace is in the house and the A/C is
on a pad outside. Noticed water on the floor today (newly refinished
hardwood). I took off the outside panels on the furnace and there's plenty
of leakage. Seems to be just water.

Any suggestions on how to proceed?

Thanks,
mc


RP

2005-06-30, 4:25 am



Mike Cummins wrote:
quote:

> I have an older model Sears furnace. Furnace is in the house and the A/C is
> on a pad outside. Noticed water on the floor today (newly refinished
> hardwood). I took off the outside panels on the furnace and there's plenty
> of leakage. Seems to be just water.
>
> Any suggestions on how to proceed?


Find the other end of the condensate line.

hvacrmedic





lp13-30

2005-06-30, 4:25 am

A/C condensate drain line is most likely stopped up. It will be on the
bottom of the a/c coil just above the furnace. If it drains outside, try
to hook up a wetvac to the pipe outside and suck the crud out of the
pipe from the outside. If it goes into the sewer, disconnect it and blow
it out. There are other possible causes beside the line itself, but they
are best left to an a/c tech. Larry