Home > Archive > Home Automation > September 2006 > x10 Yard lighting rnnng cable question









You are viewing an archived Text-only version of the thread. To view this thread in it's original format and/or if you want to reply to this thread please [click here]

 

Author x10 Yard lighting rnnng cable question
Imran

2006-08-02, 1:25 pm

Hello,

I am building a retaining wall and a 2 tier garden system, within the
retaining wall I will be istalling 240V Brick lighth approx 22 lights in
total connected to 3 different X10 Relay Receiver (DIN Mounted)
AD10, these DIN devices will be installed into a IP-66 rated weather proof
distribution board that will be connected to my mains box.

I do have a problem thought I have to run underground conduit under a
pathway, the local rules require a minimum depth for the conduit of 50cm and
I am in the process of digging the trenches at the moment. Is there any
suggestions from the gurus out there of how to get underneath the path
without breaking it ? I was thinking of using a metal tube or a wooden steak
to hollow out the ground but if there is an easier way I would love to hear
it.

Thanks for that help
Imran



D&SW

2006-08-02, 8:25 pm

Although messy, I have used a garden hose with high pressure nozzle. Use the
hose in conbination with a pipe to push hose under path.

"Imran" <messenger_boy_2005@hotmail.com> wrote in message
news:12d1edvmut3e8da@corp.supernews.com...
> Hello,
>
> I am building a retaining wall and a 2 tier garden system, within the
> retaining wall I will be istalling 240V Brick lighth approx 22 lights in
> total connected to 3 different X10 Relay Receiver (DIN Mounted)
> AD10, these DIN devices will be installed into a IP-66 rated weather proof
> distribution board that will be connected to my mains box.
>
> I do have a problem thought I have to run underground conduit under a
> pathway, the local rules require a minimum depth for the conduit of 50cm
> and I am in the process of digging the trenches at the moment. Is there
> any suggestions from the gurus out there of how to get underneath the path
> without breaking it ? I was thinking of using a metal tube or a wooden
> steak to hollow out the ground but if there is an easier way I would love
> to hear it.
>
> Thanks for that help
> Imran
>
>
>



IVB

2006-08-08, 3:25 am

yep, that's what the dude I hired did when I needed to run irrigation pipe
under the sidewalk. He had a special pipe/nozzle though. You could check an
irrigation equipment store.

-----------------------------------------------------
Note: I am a mere end-user with no financial stake in any products that I
may discuss.

My Personal Website w/my Home Automation PC:
http://www.myhomeautomationpc.com, last updated 4/11

My Home Automation Blog: http://homeautomation.wordpress.com/
"D&SW" <dsweatherwax@verizon.net> wrote in message
news:GzaAg.7770$oz.2675@trnddc07...
> Although messy, I have used a garden hose with high pressure nozzle. Use
> the hose in conbination with a pipe to push hose under path.
>
> "Imran" <messenger_boy_2005@hotmail.com> wrote in message
> news:12d1edvmut3e8da@corp.supernews.com...
>
>



Bill Kearney

2006-09-08, 1:25 pm

> I am in the process of digging the trenches at the moment. Is there any
> suggestions from the gurus out there of how to get underneath the path
> without breaking it ? I was thinking of using a metal tube or a wooden

steak
> to hollow out the ground but if there is an easier way I would love to

hear
> it.


I've done it with a length of PVC pipe and the male part of a hose repair
kit. Insert the threaded part of the kit into the end of a length of PVC
pipe. Thread the garden hose into the other end. Use the water pressure
and a some 'gouging' motion to push the pipe under the walkway. The hassle
with this is you'll need to dig a trench perpendicular to the pathway that's
deep enough to allow pushing the pipe. On the other side you need only dig
a hole down to the point it'll come out. One you've made it under the
walkway you can unthread the nozzle and hose, cut the pipe to length and
leave it underground. I've done this on several paths (one up to 11'
across) and while it's messy it does work quite well.

-Bill Kearney