Home > Archive > Building and Construction > February 2007 > Extending existing wall studs









You are viewing an archived Text-only version of the thread. To view this thread in it's original format and/or if you want to reply to this thread please [click here]

 

Author Extending existing wall studs
sw

2007-02-21, 1:25 pm

I am working on completing drawings for a home in the east end of
Toronto. I am showing the existing roof being taken off to facilitate
adding a second floor. The existing wood stud walls must be extended
to satisfy an owner request for additional headroom.

Does anyone have a suggestion, or can refer me to a previous post
where wall studs are extended up, or a short stud wall is added and
securely attached to the lower stud wall without having to replace the
existing wall studs?

Thankyou in advance.

Scott.

Michael Bulatovich

2007-02-21, 1:25 pm

"sw" <baddad327@gmail.com> wrote in message
news:1172084863.600683.325110@v33g2000cwv.googlegroups.com...
>I am working on completing drawings for a home in the east end of
> Toronto. I am showing the existing roof being taken off to facilitate
> adding a second floor. The existing wood stud walls must be extended
> to satisfy an owner request for additional headroom.
>
> Does anyone have a suggestion, or can refer me to a previous post
> where wall studs are extended up, or a short stud wall is added and
> securely attached to the lower stud wall without having to replace the
> existing wall studs?
>
> Thankyou in advance.
>
> Scott.


Aren't you working with an engineer?
--


MichaelB
www.michaelbulatovich.ca


Bob Morrison

2007-02-21, 8:25 pm

In a previous post sw wrote...
> Does anyone have a suggestion, or can refer me to a previous post
> where wall studs are extended up, or a short stud wall is added and
> securely attached to the lower stud wall without having to replace the
> existing wall studs?
>


Don't mess with it. If this is platform framing then remove the studs to
the second floor and install new ones.

Otherwise, contact a local engineer for advice.

--
Bob Morrison, PE, SE
R L Morrison Engineering Co.
Structural & Civil Engineering
Poulsbo WA
bob at rlmorrisonengr dot com
M&S

2007-02-21, 8:25 pm

Bob Morrison wrote:
> In a previous post sw wrote...
>
>
>
> Don't mess with it. If this is platform framing then remove the studs to
> the second floor and install new ones.
>
> Otherwise, contact a local engineer for advice.
>


A healthy bead of wood glue and some perforated plumbers tape screwed
across the stud/plate connections wouldnt suffice?

Mark

HerHusband

2007-02-22, 1:25 pm

> I am working on completing drawings for a home in the east end of
> Toronto. I am showing the existing roof being taken off to facilitate
> adding a second floor. The existing wood stud walls must be extended
> to satisfy an owner request for additional headroom.


In most cases, framing one wall directly on top of the other would create a
pivot point. It would act sort of like a large hinge. Strong winds or
seismic forces could easily cause the wall to bend (and possibly fail) at
the point where the two walls meet.

If this wall extends unsupported from the first floor to the second, you
should tear it out and reframe with continuous studs. Then add fireblocking
every 8' or so in the studbays.

If you can't remove the existing wall for some reason, you could probably
sister full height studs next to the existing shorter studs. But, that's
probably more work than just reframing the wall.

Anthony
Bob Morrison

2007-02-22, 1:25 pm

In a previous post HerHusband wrote...
> If you can't remove the existing wall for some reason, you could probably
> sister full height studs next to the existing shorter studs. But, that's
> probably more work than just reframing the wall.
>


I could see this being the case if the wall is balloon framed. The number
of fasteners required will depend on the loads.

--
Bob Morrison, PE, SE
R L Morrison Engineering Co
Structural & Civil Engineering
Poulsbo WA
bob at rlmorrisonengr dot com
sw

2007-02-22, 1:25 pm

On Feb 22, 11:01 am, HerHusband <unkn...@unknown.com> wrote:
>
> In most cases, framing one wall directly on top of the other would create a
> pivot point. It would act sort of like a large hinge. Strong winds or
> seismic forces could easily cause the wall to bend (and possibly fail) at
> the point where the two walls meet.
>
> If this wall extends unsupported from the first floor to the second, you
> should tear it out and reframe with continuous studs. Then add fireblocking
> every 8' or so in the studbays.
>
> If you can't remove the existing wall for some reason, you could probably
> sister full height studs next to the existing shorter studs. But, that's
> probably more work than just reframing the wall.
>
> Anthony


I think you've answered my question. I believe it's best to sister a
new 2"X6" wd stud wall to the existing 2"X4". I"ll widen the base
plate to accept. We need the extra depth to obtain the min required
insulation anyways. I should clarify that there is no second floor
yet, just a roof. It's an existing bungalow whose roof we're
removing.
You were very helpful in this, thankyou once again.

longshot

2007-02-22, 1:25 pm


"sw" <baddad327@gmail.com> wrote in message
news:1172084863.600683.325110@v33g2000cwv.googlegroups.com...
>I am working on completing drawings for a home in the east end of
> Toronto. I am showing the existing roof being taken off to facilitate
> adding a second floor. The existing wood stud walls must be extended
> to satisfy an owner request for additional headroom.
>
> Does anyone have a suggestion, or can refer me to a previous post
> where wall studs are extended up, or a short stud wall is added and
> securely attached to the lower stud wall without having to replace the
> existing wall studs?
>
> Thankyou in advance.
>
> Scott.


you could build your mini wall like you are saying & add light gage steel
gussets to each side if you think saving the existing is worth the trouble.

>



sw

2007-02-22, 5:25 pm

On Feb 22, 2:16 pm, "longshot" <longs...@aol.com> wrote:
> "sw" <baddad...@gmail.com> wrote in message
>
> news:1172084863.600683.325110@v33g2000cwv.googlegroups.com...
>
>
>
>
>
> you could build your mini wall like you are saying & add light gage steel
> gussets to each side if you think saving the existing is worth the trouble.
>
>
>
> - Hide quoted text -
>
> - Show quoted text -


hmmm. more or less a kind of strapping on the face of the joist. I
think that the nice thing about sistering new 2x6's to the existing
2x4 is that I have more room to achieve the r value im going to need.
Good suggestion though. Thanks

Alan

2007-02-23, 3:25 am

Code won't allow extending studs this way for seismic and wind
reasons. The failure is known as "hinging", where the original top
plate rocks off the studs. However, you can support the extension
with angled supports between the new floor joists and original top
plate. This would create a strong triangle that would prevent
hinging, and so the planning department would likely accept this to
stabilize the stem wall without additional engineers ink. The other
approach would be to have a truss company design floor trusses (they
have their own engineers) that would sit on the original top plate,
but which are designed to have added ceiling clearance below.
Otherwise as said, you'll need an engineer, and many engineers aren't
too good at this sort of design work it seems to me. They are more
used to figuring out the basics of load on conventional foundation and
beam situations. But, if you are building up, you may need an
engineer to ensure the existing foundation can take the load.

On Feb 21, 11:07 am, "sw" <baddad...@gmail.com> wrote:
> I am working on completing drawings for a home in the east end of
> Toronto. I am showing the existing roof being taken off to facilitate
> adding a second floor. The existing wood stud walls must be extended
> to satisfy an owner request for additional headroom.
>
> Does anyone have a suggestion, or can refer me to a previous post
> where wall studs are extended up, or a short stud wall is added and
> securely attached to the lower stud wall without having to replace the
> existing wall studs?
>
> Thankyou in advance.
>
> Scott.



Alan

2007-02-23, 3:25 am

I forgot to add that the angle support idea would result in an unusual
interior ceiling around the perimeter, so that the 2x4 wood brackets
would need to be placed 16" on center for the wall board to attach
to. The space would be a good place to route HVAC ducts, water pipes,
or electrical wire. But then again if the ceiling/floor joists extend
out over the exterior for a sizeable overhang, these angle brackets
could be on the exterior and perhaps hidden in an architectural facade
of some sort.

On Feb 21, 11:07 am, "sw" <baddad...@gmail.com> wrote:
> I am working on completing drawings for a home in the east end of
> Toronto. I am showing the existing roof being taken off to facilitate
> adding a second floor. The existing wood stud walls must be extended
> to satisfy an owner request for additional headroom.
>
> Does anyone have a suggestion, or can refer me to a previous post
> where wall studs are extended up, or a short stud wall is added and
> securely attached to the lower stud wall without having to replace the
> existing wall studs?
>
> Thankyou in advance.
>
> Scott.



LinkBot





Other archives available: Cellular phones topics archive | Web Design forum archive | Software help archive | Hardware reviews archive | Programming topics archive

Copyright 2004 - 2008 homeownerschat.com