Home > Archive > Plumbing forum > June 2005 > Bruner Goulet Ironworker Float Valve









You are viewing an archived Text-only version of the thread. To view this thread in it's original format and/or if you want to reply to this thread please [click here]

 

Author Bruner Goulet Ironworker Float Valve
Theo Weber

2005-06-16, 2:27 pm

The old metal float valve assembly in the brine tank of my
Ironworker softener was recently replaced with a plastic one after the
float holder corroded so badly it broke. The softener seemed worked
properly once, but the next time it cycled, it proceeded to overflow.
When I checked the valve I immediately saw what the problem was. The
elbow on top of valve assembly is able to move in the sleeve it fits
into. Once the water level rises and closes the float valve, the water
pressure causes the elbow to move upwards in the sleeve and the water
continues to pump into the brine tank through the space created.
Therefore, the water level in the tank ends up being too high. The real
problem occurs when the softener cycles again. Since the elbow is not
in the sleeve properly, no suction is created and the brine water isn't
sucked into the softener during the backwash. Since the water level in
the brine tank doesn't drop, the brine refill stage overflows the tank.
I'm thinking that the elbow needs to be glued into place
permanently. Is this fix the way to go, or I have somehow gotten a
faulty replacement assembly? Cheers

Theo
LinkBot





Other archives available: Cellular phones topics archive | Web Design forum archive | Software help archive | Hardware reviews archive | Programming topics archive

Copyright 2004 - 2008 homeownerschat.com