Home > Archive > Electrical code Compliance > June 2005 > Peripheral pci cards for personal computer









You are viewing an archived Text-only version of the thread. To view this thread in it's original format and/or if you want to reply to this thread please [click here]

 

Author Peripheral pci cards for personal computer
Ray

2005-06-17, 11:29 pm

Normally such cards are operating at DC 5V/12V from the personal computer
and outside the scope of LVD
Directive. Is it ok to bear CE mark without any safety test on such items?
Or there is another directive to cover this loophole?

Thanks,

Ray



Pat Carpenter

2005-06-17, 11:29 pm

On Wed, 16 Mar 2005 01:30:45 +0800, "Ray"
<NoSpam-lizhiqiang1@GMail.com> wrote:
quote:

>Normally such cards are operating at DC 5V/12V from the personal computer
>and outside the scope of LVD
>Directive. Is it ok to bear CE mark without any safety test on such items?
>Or there is another directive to cover this loophole?
>
>Thanks,
>
>Ray
>
>

Whilst true that the LVD would not apply in this case, the CE mark
states that the item meets ALL Relevant Directives. It would be
prudent to place a document in the technical construction file that
the item has been reviewed/considered against the LVD and found to be
non-applicable (call it protecting your back) ;-)


Blue Skies
Pat Carpenter
Tomi Holger Engdahl

2005-06-17, 11:29 pm

Pat Carpenter <patandchrisandpw@btinternet.com> writes:
quote:

> On Wed, 16 Mar 2005 01:30:45 +0800, "Ray"
> <NoSpam-lizhiqiang1@GMail.com> wrote:
>
>
> Whilst true that the LVD would not apply in this case, the CE mark
> states that the item meets ALL Relevant Directives.


In the case of PCI cad for personal computer I would be more
worried about the EMC compliance.
quote:

> It would be
> prudent to place a document in the technical construction file that
> the item has been reviewed/considered against the LVD and found to be
> non-applicable (call it protecting your back) ;-)


I recommend this also.

Make the technical construction file that lists all the
relevant directives related to your equipment and how
your device complies with them. Complying with them
might mean built according some suitable standard, tested
agaist sutiable standard, directive is non-applicable
to your device etc..


--
Tomi Engdahl (http://www.iki.fi/then/)
Take a look at my electronics web links and documents at
http://www.epanorama.net/
Ray

2005-06-17, 11:29 pm

Many thanks for your useful advice. I have learnt that LVD Directive is
being revised to remove the low voltage limit in addition to others. Is it
true and where I can get the any draft for reference?

Ray

"Tomi Holger Engdahl" <then@solarflare.cs.hut.fi> wrote in message
news:laj4qfchtgf.fsf@solarflare.cs.hut.fi...
quote:

> Pat Carpenter <patandchrisandpw@btinternet.com> writes:
>
>
> In the case of PCI cad for personal computer I would be more
> worried about the EMC compliance.
>
>
> I recommend this also.
>
> Make the technical construction file that lists all the
> relevant directives related to your equipment and how
> your device complies with them. Complying with them
> might mean built according some suitable standard, tested
> agaist sutiable standard, directive is non-applicable
> to your device etc..
>
>
> --
> Tomi Engdahl (http://www.iki.fi/then/)
> Take a look at my electronics web links and documents at
> http://www.epanorama.net/